Recommendations for the dilution of concentrate G128 for manual processing of the film (in accordance with the icons located on the cans).
Pour 5 liters of concentrate into a container with 15 liters of water (water temperature from + 15ºС to + 40ºС), then stir the remaining 5 liters of water (water temperature from + 15ºС to + 40ºС).
Storage conditions for AGFA NDT chemicals:
During storage, chemical reagents should have optimal temperature limits, which, in accordance with regulatory and technical documentation, constitute a temperature range from + 4 ° C to + 23 ° C. The positive temperature range of application of these chemicals is primarily associated with a high water content in their composition. These chemical reagents at low temperatures (up to -50 ° C) slightly change their physico-chemical properties.
In case of freezing of chemical reagents, it is necessary to thaw them at room temperature and use them as usual. The same applies to chemical reagents of the STRUCTURIX brand for automatic X-ray film processing.
The table shows data on the configuration and consumption of chemical reagents. These data will also allow to determine the total weight and dimensions when delivering the required amount of chemicals.
Retail Packaging Transport Packaging (box)
Name Retail Package Supply of finished solution Weight, kg
Weight, kg
Length, cm Width, cm Height, cm
Manual processing (1 box = 4 cans)
G128 Liquid concentrate, canister 5 l for ready-made solution 25 l 1 l / 1 m² of film 6.9 27.6 37.9 29.3 33.7
Developer for manual processing AGFA G128, 5 l
Нужна консультация?